{"id":38776,"date":"2025-04-24T13:27:23","date_gmt":"2025-04-24T04:27:23","guid":{"rendered":"https:\/\/monovate.net\/en\/?page_id=38776"},"modified":"2025-05-20T14:18:52","modified_gmt":"2025-05-20T05:18:52","slug":"sus_sh","status":"publish","type":"page","link":"https:\/\/monovate.net\/en\/sus_sh\/","title":{"rendered":"Shutter Valve &#8211; SH Series"},"content":{"rendered":"<div class=\"page__container category-features\">\n<h2>Shutter-Valve Overview [SH Series]<\/h2>\n<p>Stainless-steel slide-gate valves designed specifically for powders and pellets.<br \/>\nAttach them to the outlet of a tank or hopper to start\/stop discharge with a full-bore opening.<\/p>\n<div class=\"row-center\">\n<div><img decoding=\"async\" src=\"\/en\/wp-content\/uploads\/SH_01.jpg\" alt=\"Manual Shutter Valve\" class=\"img-300\"><\/div>\n<div><img decoding=\"async\" src=\"\/en\/wp-content\/uploads\/2021\/01\/shb_06.jpg\" alt=\"How to Move Shutter Valve\" class=\"img-300\"><\/div>\n<\/div>\n<div class=\"box3\">\n<span class=\"box3-title\">Contents<\/span><br \/>\n<a href=\"#type-difference\">Model Lineup &#038; Differences<\/a><br \/>\n<a href=\"#manual-series\">Manual-Operation Models<\/a><br \/>\n<a href=\"#air-series\">Air-Actuated Models<\/a><br \/>\n<a href=\"#custom-order\">Custom Options<\/a>\n<\/div>\n<h2 id=\"type-difference\">Model Lineup &#038; Key Differences<\/h2>\n<table class=\"comparison-table\">\n<tbody>\n<tr>\n<th class=\"center-text col-model\">Model<\/th>\n<th class=\"center-text col-op\">Operation<\/th>\n<th class=\"center-text col-top\">Top&nbsp;Connection<\/th>\n<th class=\"center-text col-bottom\">Bottom&nbsp;Connection<\/th>\n<th>Main Features<\/th>\n<\/tr>\n<tr>\n<td class=\"center-text\">SH<\/td>\n<td class=\"center-text\">Manual<\/td>\n<td class=\"center-text\">Ferrule<\/td>\n<td class=\"center-text\">Short-pipe<\/td>\n<td>Economical basic type. Locks to prevent accidental opening.<\/td>\n<\/tr>\n<tr>\n<td class=\"center-text\">SHB<\/td>\n<td class=\"center-text\">Manual<\/td>\n<td class=\"center-text\">Ferrule<\/td>\n<td class=\"center-text\">Ferrule<\/td>\n<td>Both ends ferrule for easy inline piping.<\/td>\n<\/tr>\n<tr>\n<td class=\"center-text\">SH-A<\/td>\n<td class=\"center-text\">Air cylinder<\/td>\n<td class=\"center-text\">Ferrule<\/td>\n<td class=\"center-text\">Short-pipe<\/td>\n<td>Hands-free opening\/closing; reduces contamination risk.<\/td>\n<\/tr>\n<tr>\n<td class=\"center-text\">SHB-A<\/td>\n<td class=\"center-text\">Air cylinder<\/td>\n<td class=\"center-text\">Ferrule<\/td>\n<td class=\"center-text\">Ferrule<\/td>\n<td>Air-actuated plus double-ferrule for quick CIP removal.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<section id=\"manual-series\">\n<h3>Manual-Operation Models<\/h3>\n<div class=\"sg-series-container\">\n<div class=\"sg-series-item\">\n<img decoding=\"async\" src=\"\/en\/wp-content\/uploads\/SH_01.jpg\" alt=\"SH Manual\" class=\"img-300\"><\/p>\n<h4>Shutter Valve [SH]<\/h4>\n<p>Slide-gate valve with ferrule inlet and beaded short-pipe outlet; PTFE seat for smooth action.<br \/>\n<a class=\"link_b\" href=\"\/en\/products\/sh\">View Details&nbsp;&gt;&gt;<\/a>\n<\/div>\n<div class=\"sg-series-item\">\n<img decoding=\"async\" src=\"\/en\/wp-content\/uploads\/2021\/01\/shb_01.jpg\" alt=\"SHB Manual Double-Ferrule\" class=\"img-300\"><\/p>\n<h4>Shutter Valve Double-Ferrule [SHB]<\/h4>\n<p>Both ends ferrule; easy inline mounting between pipes or vessels.<br \/>\n<a class=\"link_b\" href=\"\/en\/products\/shb\">View Details&nbsp;&gt;&gt;<\/a>\n<\/div>\n<\/div>\n<p class=\"center-text\"><a class=\"contact_btn\" href=\"#contact\">REQUEST QUOTE<\/a><\/p>\n<\/section>\n<section id=\"air-series\">\n<h3>Air-Actuated Models<\/h3>\n<div class=\"sg-series-container\">\n<div class=\"sg-series-item\">\n<img decoding=\"async\" src=\"\/en\/wp-content\/uploads\/SH-A_01.jpg\" alt=\"SH-A Air\" class=\"img-300\"><\/p>\n<h4>Air-Actuated Shutter Valve [SH-A]<\/h4>\n<p>Integrated stainless cylinder (double-acting). Ideal for automated powder lines.<br \/>\n<a class=\"link_b\" href=\"\/en\/products\/sh-a\">View Details&nbsp;&gt;&gt;<\/a>\n<\/div>\n<div class=\"sg-series-item\">\n<img decoding=\"async\" src=\"\/en\/wp-content\/uploads\/SHB-A_01.jpg\" alt=\"SHB-A Air Double-Ferrule\" class=\"img-300\"><\/p>\n<h4>Air-Actuated Shutter Valve Double-Ferrule [SHB-A]<\/h4>\n<p>Cylinder + ferrule\/ferrule ends for quick CIP removal.<br \/>\n<a class=\"link_b\" href=\"\/en\/products\/shb-a\">View Details&nbsp;&gt;&gt;<\/a>\n<\/div>\n<\/div>\n<p class=\"center-text\"><a class=\"contact_btn\" href=\"#contact\">REQUEST QUOTE<\/a><\/p>\n<\/section>\n<h2 id=\"contact\">Request a Quote<\/h2>\n<div class=\"contact-iframe\">\n<iframe src=\"https:\/\/monovate.form.kintoneapp.com\/public\/40d405631e2e020fbfcc6d139fd29e21b158070eea2bc7b61623ba14dff37cc9?iframe=true\" width=\"100%\" height=\"1024\" frameborder=\"0\" scrolling=\"auto\"><\/iframe>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Shutter-Valve Overview [SH Series] Stainless-steel slide-gate valves designed specifically for powders and pellets. Attach them to the outlet of a tank or hopper to start\/stop discharge with a full-bore opening. Contents Model Lineup &#038; Differences Manual-Operation Models Air-Actuated Models Custom Options Model Lineup &#038; Key Differences Model Operation Top&nbsp;Connection Bottom&nbsp;Connection Main Features SH Manual Ferrule [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-full-width.php","meta":{"_acf_changed":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-38776","page","type-page","status-publish","hentry"],"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/monovate.net\/en\/wp-json\/wp\/v2\/pages\/38776","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/monovate.net\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/monovate.net\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/monovate.net\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/monovate.net\/en\/wp-json\/wp\/v2\/comments?post=38776"}],"version-history":[{"count":24,"href":"https:\/\/monovate.net\/en\/wp-json\/wp\/v2\/pages\/38776\/revisions"}],"predecessor-version":[{"id":38900,"href":"https:\/\/monovate.net\/en\/wp-json\/wp\/v2\/pages\/38776\/revisions\/38900"}],"wp:attachment":[{"href":"https:\/\/monovate.net\/en\/wp-json\/wp\/v2\/media?parent=38776"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}